Teknik Veriler

TECHNICAL DATA

Fuel gas and oil (in some countries also wood, pellets, corn)
Operating temperature in flue gases 250 °C (in certain countries: 450°C)
Cold resistance -50 °C
Wall thickness 2-2,5 mm
Diameter 60-900 mm (optional within this range)
Length (optional) 3-81 m (minimum and maximum length installed so far)
Corrosion resistance very good in respect of acids pH 1-7
good in respect of bases pH 7 - max. 12
Density 1,5 g/cm3
Tensile strength 100-150 N/mm2
Thermal conductivity 0,4 W/m K
Coefficient of thermal expansion 2,4 x 10-5 m/m K
Angle of distortion 30° max.
Flame resistance at 1000 °C 10 minutes
EU classification (EN-14471) T250 P1 W3 R1 050 E
T250 maximum temperature of input flue gas (Sweden, Slovakia, Romania: T450, Hungary: T200).
P1 pressure resistance: value measured after exposed to 200 Pa of thermal load;
W3 corrosion resistance: resistant to the condensates of gas, oil and solid fuel;
R1 thermal resistance: the reciprocal value of thermal conductivity related to wall thickness;
0 resistance to soot fire: not resistant;
50 distance of combustible materials: a distance of a minimum of 50 mm is allowed between the wall of the chimney liner and a combustible object;
E suitable for installation as an internal flue gas outlet, and it can also be freestanding.

 

 

Harmful material emission none appears between 100 °C-600 °C Measurements performed by: Dansk Toxicology Center (Denmark),
Institute für Ökologische Chemie (Germany)
 
There are no heavy metals or halogen compounds, and no carcinogenic materials or materials causing permanent health damage
occur in the material of FuranFlex®.
 
FuranFlex® does not contain antimony trioxide. Measurements performed by: Budapest University of Technology and Economics
Air tightness (1.5-hour thermal treatment at 400 °C, then measured at 20 °C)
Pressure (Pa) 100 200 5000
Measured air loss (l/m2h)
((T-section included in the measurement)
24 38 360
Measured air loss (l/m2h)
(pipe cut off above T-profile, measured without this section)
16 32 268

Measurements performed by: CSTB (Paris)
Permitted height of freestanding self-supported FuranFlex® chimney liner tube
 
Diameter (mm) 140 275 340
Permitted height (m)
(With a three-times safety factor)
286 299 202

Measurements performed by: CSTB (Paris)
 